Sign In | Join Free | My himfr.com
Home > Fluke Multifunction Calibrator >

TD1050A Calibration Device Easy Traceability For AC DC Clamp Meter

Product Categories
Tunkia Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap TD1050A Calibration Device Easy Traceability For AC DC Clamp Meter from wholesalers
     
    Buy cheap TD1050A Calibration Device Easy Traceability For AC DC Clamp Meter from wholesalers
    • Buy cheap TD1050A Calibration Device Easy Traceability For AC DC Clamp Meter from wholesalers

    TD1050A Calibration Device Easy Traceability For AC DC Clamp Meter

    Ask Lasest Price
    Brand Name : TUNKIA
    Price : negotiation
    Payment Terms : negotiation
    • Product Details
    • Company Profile

    TD1050A Calibration Device Easy Traceability For AC DC Clamp Meter

    TD1050A Calibration Device for Clamp Meter

    Introduction

    • TD1050A, a calibration device for clamp ammeters. The optional accuracy are 0.02% and 0.05%.

    • The device calibrates the AC/DC clamp ammeters by single coil with high accuracy and easy traceability, and has the functions of AC/DC current output, resistance simulation, frequency/phase adjustment, power detection.

    • Meet the requirements of JJF 1075-2015 Calibration Specification for Clamp Ammeter. (Tunkia is involved in drafting)

    Features

    • Calibrate AC/DC clamp ammeters by single coil: The AC/DC current source connect to a single coil semi-circular copper ring with a diameter of 1m, can directly output AC/DC high current up to 2200 A (or 1100 A). Suitable for calibrating AC/DC clamp ammeters with high accuracy.

    • Place the clamp meter in the center of the copper ring when calibrating. The diameter of the copper bar in the center position is smaller than the other positions, which is convenient for the access of small size clamp meters.

    • Easy to open the copper ring, and thread a standard current transformer or I-V converter into the ring for calibrating the device itself regularly.

    • Reserved terminals for high current, to provide current for the calibration of DC shunts.

    • Value Adjustment Method: Fixed-point, rotary encoder, and step.

    • Frequency and Phase (Option): The AC output frequency and the phase between voltage and current is variable.

    • Power Output (Option): Test DC power, active power, reactive power, apparent power and power factor.

    • Proprietary Software (Option): Support the calibration of the checked ammeters by semi-automatic or full-automatic, data management and report export.

    Application

    Calibrated Types

    Accuracy of Calibrated Device

    0.02% Calibrator

    0.05% Calibrator

    AC/DC Ammeters

    0.1 and below

    0.2 and below

    AC/DC Voltmeters

    0.1 and below

    0.2 and below

    DC Resistance

    0.2 and below

    0.2 and below

    AC/DC Power

    0.2 and below

    0.5 and below

    DC Shunts

    0.1 and below

    0.2 and below


    Specification


    AC Voltage Output

    RangeStability (%/min)

    Accuracy (k = 2)

    (ppm*RD + ppm*RG)①

    Max. Load

    Current (mA)

    0.02%0.05%0.02%0.05%
    10 V0.0050.01120 + 80300 + 200800
    30 V0.0050.01120 + 80300 + 200700
    100 V0.0050.01120 + 80300 + 200200
    300 V0.0050.01120 + 80300 + 20070
    750 V0.0050.01120 + 80300 + 20030
    Remarks: ①: RD is the reading,RG is the range
    • Output Range of Voltage: 1 V ~ 825 V

    • Display: 6 digits

    • Resolution: 0.002 %*RG

    • Distortion: <0.5 %

    • Protection: Short-circuit protection, overload protection, overheating protection.


    AC Current Output

    ModelRangeResolutionStability (%/min)

    Accuracy (k = 2)

    (ppm*RD + ppm*RG)

    Max. Load

    Voltage (V)

    0.02%0.05%0.02%0.05%
    Small current loop100 mA1 μA0.010.01120 + 80300 + 20010
    300 mA1 μA0.010.01120 + 80300 + 20010
    1 A10 μA0.010.01120 + 80300 + 20010
    3 A10 μA0.010.01120 + 80300 + 20010
    10 A100 μA0.0050.01120 + 80300 + 20010
    30 A100 μA0.0050.01120 + 80300 + 2005
    100 A1 mA0.0050.01120 + 80300 + 2005
    High current loop250 A1 mA0.010.01120 + 80300 + 2007
    500 A1 mA0.010.01120 + 80300 + 2007
    1000 A10 mA0.0050.01120 + 80300 + 2007
    2000 A②10 mA0.0050.01120 + 80300 + 2007
    Remarks: ②: 2100 A for option
    • Output Range of Current: 10 mA ~ 1100 A (2100 A);

    • Range Switching: Automatic or Manual

    • Resolution: 0.002 %*RG

    • Distortion: <0.5 % (except 1 kA/2 kA); <1 % @ 1 kA/2 kA range

    • Protection: Short-circuit protection, overload protection, overheating protection.


    Frequency

    TypeRangeAdjust finenessAccuracy (k = 2)
    Frequency

    40.000 Hz ~ 400.000 Hz

    (1 kHz can be customized)

    0.001 Hz0.005%*RD

    DC Voltage Output

    RangeStability (%/min)

    Accuracy (k = 2)

    (ppm*RD + ppm*RG)

    Max. Load

    Current (mA)

    0.02%0.05%0.02%0.05%
    200 mV0.0050.01120 + 80300 + 200100
    1 V0.0050.01120 + 80300 + 200100
    10 V0.0050.01120 + 80300 + 200100
    30 V0.0050.01120 + 80300 + 200600
    100 V0.0050.01120 + 80300 + 200200
    300 V0.0050.01120 + 80300 + 20060
    600 V0.0050.01120 + 80300 + 20025
    1000 V0.0050.01120 + 80300 + 20020
    • Output Range of Voltage: 20 mV to 1100 V

    • Resolution: 0.002 % of range

    • Ripple Coefficient: <1 %

    • Protection: Short-circuit protection, overload protection, overheating protection.


    DC Current Output

    ModelRangeResolutionStability (%/min)

    Accuracy (k = 2)

    (ppm*RD + ppm*RG)

    Max. Load

    Voltage (V)

    0.02%0.05%0.02%0.05%
    Small current loop100 mA1 μA0.0050.01150 + 50300 + 10010
    300 mA1 μA0.0050.01150 + 50300 + 10010
    1 A10 μA0.0050.01150 + 50300 + 10010
    3 A10 μA0.0050.01150 + 50300 + 10010
    10 A100 μA0.0050.01150 + 50300 + 10010
    30 A100 μA0.0050.01150 + 50300 + 1005
    100 A1 mA0.0050.01150 + 50300 + 1005
    High current loop250 A1 mA0.0050.01150 + 50300 + 1005
    500 A1 mA0.0050.01150 + 50300 + 1005
    1000 A10 mA0.0050.01150 + 50300 + 1005
    2000 A②10 mA0.0050.01150 + 50300 + 1005
    Remarks: ②: 2100 A for option
    • Output Range of Voltage: 20 mA ~ 1100 A (2100 A);

    • Resolution: 0.002 %*RG

    • Range Switching: Automatic or Manual

    • Distortion: <0.5 % (except 1 kA/2 kA); <1 % @ 1 kA/2 kA range

    • Protection: Short-circuit protection, overload protection, overheating protection.


    Power Output (Option)

    TypeRangeAccuracy (k = 2), (%*FS)③
    0.02%0.05%
    DC PowerCombination of DC voltage and current range.0.050.1
    Active Power |cosφ|≥0.5Combination of AC voltage and current range.0.050.1
    0.50.050.1
    Reactive Power |sinφ|≥0.50.050.1
    Power Factor-1.0000…0.0000…+1.00000.050.1
    0.050.1
    Remark: ③: FS = Voltage range × Current range

    Resistance

    RangeResolutionAllowable Current

    Accuracy (k = 2)

    (ppm*RD + ppm*RG)

    100 Ω1 mΩ300 + 200300 + 200
    1 kΩ10 mΩ300 + 200300 + 200
    10 kΩ100 mΩ300 + 200300 + 200
    100 kΩ1 Ω300 + 200300 + 200
    1 MΩ10 Ω300 + 200300 + 200
    10 MΩ100 Ω600 + 400600 + 400
    100 MΩ1 kΩ10 nA ~ 50 nA3000 + 2000
    • Output Range of Resistance: 10 Ω ~ 110 MΩ

    • Display: 6 digits


    Quality TD1050A Calibration Device Easy Traceability For AC DC Clamp Meter for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Tunkia Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)