Sign In | Join Free | My himfr.com
Home > Fluke Multifunction Calibrator >

AC Electrical Power Calibrator TA2100 Multi Value High Precision

Product Categories
Tunkia Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap AC Electrical Power Calibrator TA2100 Multi Value High Precision from wholesalers
     
    Buy cheap AC Electrical Power Calibrator TA2100 Multi Value High Precision from wholesalers
    • Buy cheap AC Electrical Power Calibrator TA2100 Multi Value High Precision from wholesalers

    AC Electrical Power Calibrator TA2100 Multi Value High Precision

    Ask Lasest Price
    Model Number : TA2100
    Brand Name : TUNKIA
    Price : negotiation
    Payment Terms : negotiation
    • Product Details
    • Company Profile

    AC Electrical Power Calibrator TA2100 Multi Value High Precision

    TA2100 AC Power Calibrator

    Introduction

    • TA2100 a wide-range, multi-value and high-precision calibrator, can accurately output ultra-precision AC voltage, current and power, with two specifications of 0.02% and 0.05%.

    • It is suitable for calibrating AC power analyzers, AC power meters, AC voltmeters, and AC ammeters.

    Features

    • Electrical Parameters Output: Voltage is up to 1100 V, current is up to 110 A at a frequency of 45 Hz ~ 70 Hz (400 Hz optional).

    • AC power output: calibrate the active power, reactive power, apparent power and power factor of the meter under test.

    • Value Adjustment Method: Fixed-point, rotary encoder, step and potentiometer (option).

    • Output Switch: The output can be turned on/off arbitrarily by one-touch operation.

    • Statistical analysis function: Automatically record the maximum and minimum values of electricity, calculate the average value and standard deviation, and analyze the stability.

    • High reliability of the whole machine: with overload protection, voltage short circuit protection, current open circuit protection, overheating protection, etc.

    • Excellent Human-Computer Interaction: Large LCD touch screen display, touch and button operation modes, easy for users to measure manually.


    Specification

    AC Voltage Output ACV

    RangeResolutionStability (%/min)AccuracyMax. Load Current (mA)Distortion (%)
    0.05%0.02%0.05%0.02%
    3 V10 μV0.010.005300 + 200120 + 80600< 0.5
    10 V100 μV0.010.005300 + 200120 + 80600< 0.5
    30 V100 μV0.010.005300 + 200120 + 80600< 0.5
    100 V1 mV0.010.005300 + 200120 + 80500< 0.5
    300 V1 mV0.010.005300 + 200120 + 80150< 0.5
    600 V1 mV0.010.005300 + 200120 + 8080< 0.5
    1000 V10 mV0.010.005300 + 200120 + 8050< 0.5
    • Output Range: 0.3 V ~ 1100 V; Resolution: 0.001 %*RG;

    • Short circuit protection, overload protection


    AC Current Output ACI

    RangeResolutionStability (%/min)AccuracyMax. Load Voltage (mA)Distortion (%)
    0.05%0.02%0.05%0.02%
    3 mA10 nA0.010.005300 + 200120 + 8060< 0.5
    10 mA100 nA0.010.005300 + 200120 + 8060< 0.5
    30 mA100 nA0.010.005300 + 200120 + 8060< 0.5
    100 mA1 μA0.010.005300 + 200120 + 8060< 0.5
    300 mA1 μA0.010.005300 + 200120 + 8060< 0.5
    1 A10 μA0.010.005300 + 200120 + 8060< 0.5
    3 A10 μA0.010.005300 + 200120 + 8030< 0.5
    10 A100 μA0.010.005300 + 200120 + 806< 0.5
    30 A100 μA0.010.005300 + 200120 + 803< 0.5
    100 A1 mA0.010.005300 + 200120 + 801.5< 0.5
    • Output Range: 0.3 mA ~ 110 A; Resolution: 0.001 %*RG;

    • Open circuit protection, overload protection


    AC Small Voltage Output

    RangeResolutionStability (%/min)AccuracyDistortion (%)
    0.05%0.02%0.05%0.02%
    5 mV10 nV0.020.02300 + 2120 + 1< 0.5
    20 mV100 nV0.010.01300 + 4120 + 2< 0.5
    50 mV100 nV0.010.005300 + 10120 + 5< 0.5
    200 mV1 μV0.010.005300 + 40120 + 15< 0.5
    500 mV1 μV0.010.005300 + 100120 + 40< 0.5
    2 V10 μV0.010.005300 + 400120 + 150< 0.5
    5 V10 μV0.010.005300 + 1000120 + 400< 0.5
    • Output Range: 0.5 mV ~ 6 V; Resolution: 0.001 %*RG;

    • Short circuit protection, overload protection; This output is suitable for the small signal input of the sensor of the power analyzer.


    AC Power Output

    TypeStability (%/min)Accuracy (k = 2) %*FS
    0.05%0.02%0.05%0.02%
    Active Power0.010.0050.050.02
    Reactive Power0.010.010.10.05
    Apparent Power0.020.010.050.02
    Power Factor0.020.010.10.02

    • Output Range of AC Power: Combination of AC voltage range and AC current range.

    • Range of Power Factor: -1.0000…0.0000…+1.0000

    • Active Power (|cosφ| ≥0.5), Reactive Power (|sinφ| ≥0.5)

    Frequency and Phase


    • Range of Frequency: 45.000 0 Hz ~ 70.000 0 Hz

    • Resolution of Frequency: 0.000 1 Hz

    • Accuracy of Frequency: 0.005 Hz

    • Range of Phase: 0.000 ° ~ 359.999 °

    • Resolution of Phase: 0.001 °

    • Accuracy of Phase: 0.05 ° (0.05%), 0.02 ° (0.02%)

    Quality AC Electrical Power Calibrator TA2100 Multi Value High Precision for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Tunkia Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)